Nomenclature Guide

This page is your go-to resource for understanding the model numbers and codes used in our products. Whether you’re looking to decode specifications or learn more about the industry, you’ll find everything you need to navigate our product lineup with ease.

RR Series

NOTE:

Not all descriptors may appear for each model. See individual product specification documents for complete model number configuration options

Glossary

Section Digit Codes Description

Brand

F–First Co

First Co. is a leading manufacturer of multi-occupant and commercial industry HVAC products.

Cabinet Configuration

RUNV
LUNV
BFLX
BFRX
BFXX
BLXX
BRLX
BRXX

BTFX
BTLX
BTRX
BTXX
LBXX
LFBX
LFRX
LFXX

LRBX
LRXX
LTBX
LTFX
LTRX
LTXX
RBXX
RFBX

RFLX
RFXX
RLBX
RLXX
RTBX
RTFX
RTLX
RTXX

Cabinet Configuration refers to the supply openings and riser location. The first digit is the riser’s location into the unit (R – Right, L – Left, B – Rear). The second digit is the type of first supply opening discharge (U – Universal, F – Front, L – Left, R – Right, T – Top, B – Rear). The third digit is the type of optional second supply opening discharge (F – Front, L – Left, R – Right, T – Top, B – Rear). The fourth digit is unused at this time and will remain “X”. Universal means all supply openings are knockouts.

Cabinet Height

88–88″ Standard
65–65″
76–76″

80–80″
XX–Special Selection

Please select the desired cabinet height. Note: adjusted heights will restrict available cabinet configurations.

Coil Configuration

30–3 Row
40–4 Row
31–3 Row/1 Row

32–3 Row/2 Row
41–4 Row/1 Row

Multiple rows of tubes increase the coil’s surface area allowing it to transfer more heat to the air passing over the coil.

Coil Connection Side

L–Left Hand

R–Right Hand

The hot water supply should be connected to the bottom connection of the coil on one side. Please select which side of the unit you prefer the coil connection.

Coil Selection Options

Coil Handing–Left or Right
Connection–Single Side
Coil Wrapper–Galvanized Steel
Fin Material-Aluminum
Pressure Test–350 PSI (2.41 Mpa)

Coil handing describes at which side of the coil the header tubes are located, with airflow flowing from behind to front. A single side connection means combination coils have both headers on the same side. Galvanized steel is used to encase the coil and secure it to the unit. Fin coils are constructed of aluminum. The coils are pressure tested to 350 PSI.

Coil System

A–2-Pipe Cooling
B–2-Pipe Heating
C–2-Pipe Heat/Cool
D–2-Pipe Heat/Cool/Aux Heat
E–2-Pipe Cool/Electric Heat
F–4-Pipe Heat/Cool

A 2-pipe system has one pipe for hot water supply and one for return, and can provide heating or cooling at any given time depending on the water source. A 4-pipe system has two separate pipes for hot water and two for chilled water allowing for simultaneous heating and cooling in different zones of a building.

Control Voltage

A–24V Control

Amount of voltage that operates the controls system

Heat Option

KW Heat

A higher kW in HVAC indicates more capacity for heating or cooling, but it must be matched with the specific requirements of the space and considered alongside efficiency ratings to ensure optimal performance and energy consumption.

Installation

F – Furred In
E – Exposed Cabinet
R – E RV Furred In

A cabinet that has been “furred in” has been built into the wall behind sheet rock. An exposed cabinet can be painted to sit directly and open in the designated space. An ERV Furred In unit has an energy recovery ventilator.

Insulation

D-Fiberglass Dual Density
F–Foil Faced

Dual – Density Fiberglass is the standard insulation. The combination of a high-density skin and low-density core provides high acoustical values in the high and low frequency ranges normally encountered in HVAC equipment. Foil – Face Insulation has a reflective foil layer attached to one or both sides which reflects radiant heat, reducing heat transfer.

Insulation Thickness

2–½” Insulation

3–¾” Insulation

Please select the desired thickness of insulation.

Motor Type

E–ECM (3-SPEED)

Electronically Commutated Motors are a type of variable speed motor with built-in inverters and microprocessors that adjust speed based on demand.

Series

VCB, VFB, VSB
WCB
SHWC, SHWX

WHDC, WHDX
SVWX

Name of product family

Unit Size

CFM

An air-conditioner’s unit size or nominal capacity is the output level it can handle when functioning in either cooling or heating mode. Cubic feet per minute (CFM) measures how much airflow volume passes through a space in a minute.

Voltage

120 / 1Ph / 60Hz
208 / 1Ph / 60Hz
277 / 1Ph / 60Hz

Voltage is the electrical pressure that pushes an electric current through a circuit. Higher voltage indicates a more powerful pressure. Most HVAC systems use with 115 V (120 V) or 230V depending on size and capacity.

OPTIONS

Cabinet Options

Drain Pan
Filter Frame
Filter Option

Option 1
Option 2

Galvanized or Stainless Steel
1” Standard Frame
1” MERV 3, 4, or 10

Standard Access or Sound Barrier
None or Line of Sight Baffle

Electrical Options

Service Switch
Fuses
Heater Relay
Thermostat Connection
Float Switch

15A, 30A, 40A, 50A
Toggle Switch, 60A Pull Switch
None
None, Electro-Mechanical
None, Multi-Pin Connector, Terminal Block
None, Float Switch

Controls Options

Thermostats

Thermostat Location
Thermostat Option

None, Fan Switch Only, Non-Prog Manual, Non-Prog Auto, Non-Progw/LCD,
Programmable w/LCD, Programmable w/ Large LCD
None, Unit Mount, Remote Mount, ADA Unit Mount
None